Friday, 3 February 2017

Emergency Mobile Charger using DC motor


Introduction


This is a hobby project which can be made by anyone following some very simple instructions. The charger works on the principle of DC motor being used as a generator converting mechanical energy to electrical energy. But since the voltage required by a phone is 5V a voltage regulator IC 7805 is used to get the desired output voltage from the DC motor. 

Items required

1. Geared DC motor 12V – 60RPM (Available here:
https://goo.gl/Sdfr5C)
2. Voltage regulator IC 7805 (Available here: https://goo.gl/BN0Tnn)
3. Male – female USB cable (Available here: https://goo.gl/cv3f45)
4. Glue Gun (Available here: https://goo.gl/hVzVlh)


How it works?

When the shaft of the DC motor is rotated a DC voltage is induced at the terminals. But since its not possible for a human being to maintain a constant RPM of the shaft the output voltage of the motor keep varying at some time going beyond 5V which is above the save limit of the phones. Thus an IC 7805 is used to regulate the voltage and to make sure that we have a constant 5V.

The following are the steps to be followed: 

1.      Cut out the female end of the USB cable and clip of the data cables. (We require only RED and BLACK wires)
2.      Now using a solder iron make the following connections as given below : 
3.      Paste the IC 7805 and female USB port on the surface of the motor using a glue gun so as to secure it on the surface.
4.      Use a right angled iron rod at the shaft as handle for the ease of rotation.
5.   Bingo! now you are ready to test your ‘Emergency Mobile Charger’

For more information watch the video here: 






Friday, 20 May 2016

Why do transformers fail?

Introduction

There are many initiators of transformer failures, but those which can potentially lead to catastrophic failure are: 

1. Mechanical failure
2. Dielectric failure

In both cases, the transformer is no longer able to perform its intended function of carrying load and stepping down (or up) the voltage. Some of the most common reasons are listed below : 
Most Common Causes of Failures 

Lighting Surges
Line Surges/External Short Circuit 
Poor Workmanship-Manufacturer     
Deterioration of Insulation
Overloading
Moisture
Inadequate Maintenance
Sabotage, Malicious Mischief
Loose Connection

It can be a very catastrophic and dangerous situation when a transform fails as it can be seen  in the below video: 

1. So why does a transformer fail after all?

 Transformer Failure 
Failures appear in different ways, depending on the type of construction. Some modes of failure can occur regardless of construction type. These might include tap changer failures, bushing failures, tank failures, moisture ingress, and other forms of dielectric fluid contamination. Sometimes the failure could be purely due to lack of regular maintenance or lack of awareness. And sometimes it could be due to natural causes like lightning which causes electrical surge in the power lines. 


1.1 Mechanical failures

Mechanical failures can be the result of shipping damage, seismic activity, and thru-faults. The obvious result of a mechanical failure is the displacement of winding turns or damage of the turns by the forces exerted during the damaging
Doble M5400 SFRA TEST KIT
event. Mechanical failure can result in scalloped conductors (beam failure), conductors which have been looped over adjacent turns by the hoop stress (hoop failure), or in rare cases, conductors which have been severed by the tension applied by the hoop force. That’s why it’s highly recommended to perform a SFRA (Sweep Frequency Response Test) test on site to observe any change in the SFRA test result in comparison to the factory results. Moreover change in low voltage excitation current, a change in impedance, and sometimes, the presence of partial discharge (PD) during an induce voltage test can also give valuable indications about a mechanical failure in the transformer. Mechanical failure is often discovered by electrical failures which are the result of mechanical deformation.


1.2 Electrical failures

Inter turn fault
Electrical failures are the result of insulation degradation. This can be caused by thermal degradation over the life of the transformer, by thermal degradation due to excessive or frequent fault current, or by dielectric breakdown due to high voltage stress. A dielectric breakdown can also be the result of mechanical forces tearing the insulation. The result of a electrical failure can be a turn to turn failure. The consequences can be arc from the energized winding to an adjacent winding or to ground. It is important to note that overloads rarely result in transformer failures, but do cause thermal aging of winding insulation. When a transformer becomes hot, the insulation on the windings slowly breaks down and becomes brittle over time. The rate of thermal breakdown approximately doubles for every 10°C. 10°C is referred to as the “Montsinger Factor” and is a rule of thumb describing the Arrhenius theory of electrolytic dissociation. Because of this exponential relationship, transformer overloads can result in rapid transformer aging. When thermal aging has caused insulation to become sufficiently brittle, the next fault current that passes through the transformer will mechanically shake the windings, a crack will form in the insulation, and an internal transformer fault will result.
Transformer oil leakage between the tank and the radiator

Transformer can also fail due to poor maintenance. Especially when there are leakages in the transformer tank and the transformer oil level drops below a certain level which gives rise to local heating in the windings which will eventually fail if there is no transformer oil to cool down the temperature. Thus it's very essential to carryout regular oil filtration of the transformer and leak arrests  before it becomes very critical. Preventive maintenance is the key to avoid such kinds of disasters. 


1.3 Other common failure nodes

Other failure modes can be the result of a grounded core or core clamping structures (such as through-bolts) that develop shorts. These result in a shorted turn (the core) and produce high currents which are often detected by dissolved gas analysis.

2.0 Conclusion 


Maintenance is the key to avoid transformer failure: a planned program of maintenance, inspection and testing can significantly reduce the number of transformer failures, and the unexpected interruption of power. Gas-in-oil analysis should be performed annually to measure the dissolved gases in the oil that are created by developing faults in the transformer. Additional measures may include: 

  • On liquid-cooled units, check the radiators for leaks, rust, accumulation of dirt, and any mechanical damage that would restrict the oil flow.  
  • Keep the porcelain bushings and insulators clean.  
  • Keep electrical connections tight.  
  • Inspect tap changes on a regular basis.  
  • The transformer windings, bushings, and arresters should have a Power Factor test on a three-year basis.  
  • Check the ground connection on the surge arrester annually. 



catastrophic transformer failure

Saturday, 30 April 2016

Wireless Solar Tracking System with LabVIEW and Arduino

Introduction

This was the final year project for my engineering course at Manipal Institute of Technology, Manipal. The solar tracking works on the principal of astronomical equations which calculates the coordinates of the sun by calculating the elevation and azimuth angle given the latitude, longitude and time zone of a given place.The use of a tracking system greatly improves the power gain from solar radiation.The amount of current a PV panel produces has a direct correlation with the intensity of light the panel is absorbing. Below is a simple drawing of the system: 



How it works ?

The software uses complex mathematical astronomical equations to determine the position of the sun very accurately. The inputs required by the software includes the Latitudes, Longitudes and time zone of the location by the user. Other inputs like date, hour, minutes and seconds are taken by the LabVIEW program from the computer system itself thus minimizing the hassle of inputting all the data. The software system calculates the azimuth and elevation angle which is fed to the Arduino board wirelessly via XBee chip. This Arduino board generates a PWM signal proportional to the angle it gets from the software and this is fed to the servo motors which in turn rotate the pan tilt structure on which panel is mounted.


The project is divided into two modules: software module and hardware module. Both this modules have to work in synchronism in order to achieve solar tracking. 



One of the unique feature of the project lies in the 'Sun Trajectory Tab' .
This tab provides the information of the sun trajectory with the help of both 2D and 3D graphs along with the current position of the sun. The 2D graph is plotted ‘Elevation Angle’ vs ‘Azimuth Angle’ and the 3D graph gives a more comprehensive outlook to the trajectory of the sun with the directions marked. The trajectory of the sun for both 2D and 3D graph is plotted by simulating the algorithm from sunrise to sunset thus plotting points for each second of the day. 




The hardware module comprises of the following components: mechanical components, HS-311 servo motors, Arduino Board, XBee shield, XBee and 1W solar panel. The hardware module is responsible to hold the solar panel and aligned it to the sun to obtain the maximum efficiency from the solar panel while wirelessly communicating with the software module. 



The project is featured on LabVIEW MakerHub website to visit click here